Non-invasive ultrasonic flowmeter Series CU
Application areas
Water treatment and distribution, pharmaceutical, chemical and paper industry. Heating-cooling circuits, swimming pools and irrigation systems, fire protection installation, automotive industry and energy plants. Suitable for flow measurement of liquids such as sea water, kerosene, gas-oil, petrol, oils…
Product description
Non-invasive ultrasonic flowmeter, with the transducers installed outside the pipe. Suitable for horizontal and vertical pipes. Easy to install, without interruptions in the manufacturing process. No pressure drop and low maintenance. Good performance with liquids with suspended solids. Straight pipe run of 3 x DN before and after the flowmeter.
Technical specifications
Flow speed range:
- 0,2 … 12 m/s
Accuracy:
- +-1,5%
Diameters:
- DN80 … DN2000
Transducers ingress protection:
- IP65
Converter ingress protection:
- IP65
Liquid temperature range:
- 0 … +80ºC
Power supply:
- 90 ... 260 VAC 50 / 60 Hz
Power consumption:
- < 5 W
Flow and speed indication
Programmable analog output 4-20 mA proportional to flow rate
Volume totalizer
2 programmable outputs for flow alarms